Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS
Brand: Luxing Cables
Normal Sectional Area: 1.5-800mm2
Standard: IEC, BS, VDE, GB/T
Trademark: CHANG QING TENG
Transport Package: Wooden Drum, Steel Wooden Drum, Steel Iron Drum
Specification: 0.6/1kv
Origin: Dezhou, Shandong
HS Code: 8544492100
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS
Brand: Luxing Cables
Normal Sectional Area: 1.5-800mm2
Standard: IEC, BS, VDE, GB/T
Trademark: CHANG QING TENG
Transport Package: Wooden Drum, Steel Wooden Drum, Steel Iron Drum
Specification: 0.6/1kv
Origin: Dezhou, Shandong
HS Code: 8544492100
 
Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
 
Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.








Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Dimensions

Number of cores x nominal cross section min. breaking load of conductor strand Current rating in the air Outer diameter Total weight
mm^2 kN A mm kg/km
2x 16 RM 1,910 2,5 72 147
2x 25 RM 1,200 4,0 107 208
2x 35 RM 0,868 5,5 132 277
2x 50 RM 0,641 8,0 165 361
4x 16 RM 1,910 2,5 72 286
4x 25 RM 1,200 4,0 107 430
4x 35 RM 0,868 5,5 132 553
4x 50 RM 0,641 8,0 165 746
4x 70 RM 0,443 10,7 205 1009
4x 95 RM 0,320 13,7 240 1332
4x 120 RM 0,253 18,6 290 1632
4x 35 + 1x 35 RM 0,868/0,868 5,5/5,5 132/132 694
4x 50 + 1x 25 RM 0,641/1,200 8,0/4,0 165/107 814
4x 50 + 1x 35 RM 0,641/0,868 8,5/5,5 165/132 845
4x 70 + 1x 25 RM 0,443/1,200 10,7/4,0 205/107 1105
4x 70 + 2x 25 RM 0,443/1,200 10,7/4,0 205/107 1217
4x 70 + 1x 35 RM 0,443/0,868 10,7/5,5 205/132 1150
4x 70 + 2x 35 RM 0,443/0,868 10,7/5,5 205/132 1289
4x 95 + 1x 25 RM 0,320/1,200 13,7/4,0 240/107 1438
4x 95 + 1x 35 RM 0,320/0,868 13,7/5,5 240/132 1467
4x 95 + 2x 25 RM 0,320/1,200 13,7/4,0 240/107 1544

Our Factory 
Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Packing

Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable
Our Certificate

Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable


CONTACT US


Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

 
Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
 
Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.








Aluminum Conductorpvc/ PE/XLPE Insulated ABC Aerial Bundle Cable

Dimensions

Number of cores x nominal cross section min. breaking load of conductor strand Current rating in the air Outer diameter Total weight
mm^2 kN A mm kg/km
2x 16 RM 1,910 2,5 72 147
2x 25 RM 1,200 4,0 107 208
2x 35 RM 0,868 5,5 132 277
2x 50 RM 0,641 8,0 165 361
4x 16 RM 1,910 2,5 72 286
4x 25 RM Flat Cable

Flat Cable,Tpe Flat Data Cable,Usb Data Charging Cable,4-Core Usb Data Cable

ShenZhen Puchen Electronics Co., Ltd. , https://www.szpuchen.com

Posted on